National Synthetic Varnish Gloss
PRODUCT DESCRIPTION
It is a general-purpose synthetic varnish, based on alkyd resin for architectural decorative clear to wooden, metal, masonry etc. applications. It dries to give flexible, tough, and durable film. It has very good adhesion on interior/exterior surfaces. It is a general-purpose topcoat clear for mild corrosive environments. It is washable and available in Gloss, Semi gloss and Matt finishes.
RECOMMENDED USES
It is recommended as an architectural decorative varnish for masonry, wood, metal etc. surfaces in domestic and mild corrosive environments applications. It is not suitable for constant water immersion or over coating of zinc primed steel. It is used as a varnish clear on paneling, doors, windows, furniture etc. It is used for only air-drying purpose.
TECHNICAL DATA COLOUR, DRY FILM FINISH, DRY FILM VOLUME SOLIDS (ASTM D2697) SPECIFIC GRAVITY THEORETICAL SPREADING RECOMMENDED DFT (DRY FILM) RECOMMENDED WFT (WET FILM) FLASH POINT
Clear Glossy 42 ± 2%
Semi glossy 45 ± 2%
Matt 48 ± 2%
0.90 ± 0.05 16.5 – 14 M2/LTR
0.92 ± 0.05 18 – 15 M2/LTR
0.94 ± 0.05 19 – 16 M2/LTR
25 – 30 Microns/Coat
25 – 30 Microns/Coat
25 – 30 Microns/Coat
60 – 70 Microns/Coat
55 – 65 Microns/Coat
55 – 65 Microns/Coat
38ºC
38ºC
38ºC
DRYING TIME Drying time @ 30°C (Temperature, humidity, air movement, film thickness and number of coats all affect the drying time.)
TOUCH DRY DRY TO RECOAT HARD DRY
Rev. 05/10 Page 1/3
Glossy 8 – 10 hours 24 hours 48 hours
Semi glossy 6 – 8 hours 24 hours 48 hours
www.national-paints.com
Matt 6 – 8 hours 24 hours 48 hours
Product Code: 061 DECORATIVE COATINGS
TECHNICAL DATA SHEET
ADVANTAGES NATIONAL SYNTHETIC VARNISH – GLOSS I
Very good adhesion and durability, flexible, tough and washable coating, suitable topcoat varnish for mild corrosive environments, decorative finish.
APPLICATION INSTRUCTION Before application, the surface should be sound, clean and free from oil, grease, loose particles, dust, etc. Application can be done by the recommended application methods.
SURFACE PREPARATION
APPLICATION DATA APPLICATION METHOD CLEANING/THINNING THINNER (VOLUME) CONV. SPRAY REQUIREMENTS AIRLESS SPRAY REQUIREMENTS NOZZLE SIZE MIXING RATIO (BY VOLUME) POT LIFE @ 30ºc (100 ml)
Brush, Roller, Spray etc. National GP Thinner 5 – 10% depends on the method of application Possible Pressure : 2000 – 2200 psi 0.018” – 0.020” One pack NA
SYSTEM On National recommended system RECOMMENDED SYSTEM To be applied on prepared surface.
National Synthetic Varnish – Gloss I
:
2 coats
ADDITIONAL DATA SHELF LIFE @ 30ºC
Rev. 05/10 Page 2/3
18 months, in original sealed container, with proper storage conditions.
www.national-paints.com
Product Code: 061 DECORATIVE COATINGS
TECHNICAL DATA SHEET
HEALTH & SAFETY SAFETY PRECAUTIONS
As a general rule, avoid skin and eye contact by wearing overalls, gloves, goggles, and mask etc. Spillage on skin should immediately be removed by thorough washing with water and soap or suitable cleaner. Eye should be flushed with fresh water. Avoid inhalation of vapours and paint mist by wearing suitable mask. In the event of ingestion and eye contact, seek medical attention immediately. Painting must be carried out in wellventilated area. This product contains flammable materials and should be kept away from the sparks and open flames, smoking in the area should not be permitted. Local safety regulations should be followed.
STORAGE & HANDLING STORAGE
Store the paint in proper storage conditions as per the local regulations. Keep the paint container in sealed condition under shed, away from direct sunlight and extreme temperatures. Do not stock paint material near to any ignition sources. Do not put back the half or unused material back in original container, containing the supplied paint, to avoid contamination. Handle with care. Stir well before use.
NOTE: We warranty only the quality of our product and this data sheet is based on results obtained from experience and tests. We reserve the right to change data without prior notice. For surface preparation, safety details refer specifier and safety data. This data sheet supersedes all previous issued. Issued: 0510